Un-fasten and tighten a hose-clamp around the mounting pole.
Mark the band approximately 15 – 20 mm past the worm-screw (Figure 6)
Cut three hose-clamp bands at this point using tin-snips or equivalent tool
Fix the mounting bracket to the pole using three hose-clamps. The worm
screws should be internal to the bracket (Figure 7-2)
Figure 7. Installed mounting bracket
Mounting option 2: Wall mount
Remove top packaging insert
Identify mounting bracket
6TFGPVSTVJUBCMFTDSFXTUPæYUIFNPVOUTFDVSFMZUPBTRVBSFTFDUJPO
post, or bearer within a wall
1
2
3
1 - Mounting pole
2 - Hose-clamp (x3)
3 - Rear cable entry pilot mark